Voltage Control Unit : Model AX-01

AC Generator Parts and Servicing from Altex Electric CompanyThe voltage to be regulated is derived from the line U.V. and Neutral of the A.C. Generator. The AVR forms a closed loop system, where in the generator voltage is continuously compared with a highly stable reference. The generator phase to neutral voltage is rectified, attenuated, filtered and regulated to a suitable value.










General Description :
 
Company Name The Voltage Control Unit (AVR) is a solid state, encapsulated, state of the art design with latest technology.
Company Name The AVR is supplying power to the exciter field of A.C. generator and will maintain generator voltage within close limits from no load to full load, with a frequency change of not more than +/- 4%
Company Name Upon application or rejection of rated load, the generator voltage recovers to nominal value within 0.5 sec. However, the transient performance is mainly dependent upon the exciter & A.C. Generator design aspects.
Company Name Under some circumstances the A.C. Generator wave shape changes considerably from no-load to rated load due to the type of load, hence the r.m.s. average or the peak voltage does not stay in proportion. For more than 10% harmonic distortion, the voltage regulation may be outside the limit specified.
Company Name Unbalanced load on 3 phase A.C. Generators also produces regulation figures out side the limit.
Company Name AVR has been incorporated with special filters to perform satisfactory on non linear loads.
Company Name AVR has been tested at factory and set to standard voltage, frequency and stability prior to the despatch.

Features and Technical Specifications :
 
Input Power  
  Voltage : 240V ac rms + 10%
  Frequency : 50/60 HZ
Output Power  
  Voltage : 95V dc at 240V a.c. input
  Current : 6 Amps dc, 8 Amps for 10 secs for motor starting.
Field Resistance : 10 ohms, minimum
Build up : Less than 5V a.c. rms at AVR power input terminals.
Regulation : +/- 1% of set voltage
Voltage Adjustment : +/- 10% over 415V
Stability Adjustment : Adjustable to get stable operation and desired response.
Voltage Sensing : 415V a.c. two line sensing. AVR senses average of the generator wave form.
Response time : Less than75 milli seconds.
Under frequency Protection (FRO) : Adjustable from 40HZ to 60HZ.
Parallel Operation Facility (QDC : Adjustable droop up to 6%. 5A. CT Signal from "W" phase to be connected to terminals Q1 & Q2.
Circuit Protection : Protection against voltage transients by L-C networks and high energy suppressors.
RFI Suppression : AVR includes RFI filters to filter out the RFI generated, due to power device turn on.
Temperature drift : Typically 0.025% per degree celcius over operating temperature range.
Fuse : 4 Amps fuse provided inside the AVR box.
Operating temperature : 20 degree celcius to +60 degree celcius ambient.
Power dessipation : 10 Watts (max).
Size (LBH) : AX01 : 140x125x40
Weight : AX01 : 600 gms